Potential benefit of microencapsulation is its ability to deliver and protect incorporated ingredients such as vitamin E. Microcapsule wall properties can be changed by adding of coss-linking agents that are usually considered toxic for application. The microcapsules were prepared by a spray-drying technique using coacervation method, by depositing the coacervate formed in the mixture of chitosan and sodium lauryl ether sulfate to the oil/water interface. All obtained microcapsules suspensions had slightly lower mean diameter compared to the starting emulsion (6.85 ± 0.213 μm), which shows their good stability during the drying process. The choice and absence of cross-linking agents had influence on kinetics of vitamin E release. Encapsulation efficiency of microcapsules without cross-linking agent was 73.17 ± 0.64 %. This study avoided the use of aldehydes as cross-linking agents and found that chitosan/SLES complex can be used as wall material for the microencapsulation of hydrophobic active molecules in cosmetic industry.

Read More

Vitamin E-infused highly cross-linked polyethylene did not reduce the number of in vivo wear particles in total knee arthroplasty

Kumi Orita, Yukihide Minoda, Ryo Sugama, Yoichi Ohta, Hideki Ueyama, Susumu Takemura, Hiroaki Nakamura

Carbohydr Polym . 2021 Jan 1;251:116988. doi: 10.1016/j.carbpol.2020.116988. Epub 2020 Aug 30.

Abstract

Aims: Vitamin E-infused highly cross-linked polyethylene (E1) has recently been introduced in total knee arthroplasty (TKA). An in vitro wear simulator study showed that E1 reduced polyethylene wear. However there is no published information regarding in vivo wear. Previous reports suggest that newly introduced materials which reduce in vitro polyethylene wear do not necessarily reduce in vivo polyethylene wear. To assist in the evaluation of the newly introduced material before widespread use, we established an in vivo polyethylene wear particle analysis for TKA. The aim of this study was to compare in vivo polyethylene wear particle generation between E1 and conventional polyethylene (ArCom) in TKA.

Methods: A total of 34 knees undergoing TKA (17 each with ArCom or E1) were investigated. Except for the polyethylene insert material, the prostheses used for both groups were identical. Synovial fluid was obtained at a mean of 3.4 years (SD 1.3) postoperatively. The in vivo polyethylene wear particles were isolated from the synovial fluid using a previously validated method and examined by scanning electron microscopy.

Results: The total number of polyethylene wear particles obtained from the knees with E1 (mean 6.9, SD 4.0 × 107 counts/knee) was greater than that obtained from those with ArCom (mean 2.2, SD 2.6 × 107 counts/knee) (p = 0.001). The particle size (equivalent circle of diameter) from the knees with E1 was smaller (mean 0.5 μm, SD 0.1) than that of knees with ArCom (mean 1.5, SD 0.3 μm) (p = 0.001). The aspect ratio of particles from the knees with E1 (mean 1.3, SD 0.1) was smaller than that with ArCom (mean 1.4, SD 0.1) (p < 0.001 ).

Conclusion: This is the first report of in vivo wear particle analysis of E1. E1 polyethylene did not reduce the number of in vivo polyethylene wear particles compared with ArCom in early clinical stage. Further careful follow-up of newly introduced E1 for TKA should be carried out. Cite this article: Bone Joint J 2020;102-B(11):1527-1534.